fbpx Skip to content

47_14 Section 47: Cowl Baffle

Includes changes related to change from 4″ to 5″ oil cooler tube.

    Changelog

  • 09/23/2020

    REVISION DESCRIPTION:

    KAI Page 47-01 REV 1: “CB-00015A RIGHT AFT BAFFLE” was “CB-00015 RIGHT AFT BAFFLE”, “CB-00037 5” FLANGED DUCT” was “VA-187 4” FLANGED DUCT”.

    KAI Page 47-04 REV 1: In Step 1, “…CB-00015A…” was “CB-00015”.

    In Step 8, “Cleco, then rivet the CB-00037 5” Flanged Duct to the right aft baffle as shown.” was “Center, then clamp, the VA-187 4” Flanged Duct to the large hole in the right aft baffle.”

    Deleted Steps 9-11.

    In Figure 1, CB-00015A was CB-00015. CB-00037 was VA-187. “7X AN470AD4-4 was 6X AN470AD4-4”. Added “DO NOT RIVET callout.

    KAI Page 47-05 REV 1: In Step 3, “…CB-00015A…” was “…CB-00015…”.

    In Figure 1, “CB-00015A” was “CB-00015”, “4X AN470AD4-4” was “8X AN470AD4-4”, added “4X AN470AD4-4.5” callout.

    KAI Page 47-07 REV 1: In Step 1, added “Allow the RTV to fully cure before installing the baffles.

    Figures 2 and 3 updated to depict CB-00015A.

    KAI Page 47-12 REV 1: In Step 1, added “Allow the RTV to fully cure before installing the baffles”.

    KAI Page 47-13 REV 1: Figure 1 updated to depict CB-00015A.

    KAI Page 47-14 REV 1: In Step 5, “Fabricate one or more CB-00038 Tension Rod Tubes…” was “Fabricate one or more CB-00037 Tension Rod Tubes…”

    In Figure 1, “CB-00038” was “CB-00037”